Test Code ANAPL Antinuclear Antibodies (ANA), Panel
Useful For
This test is a highly sensitive, automated immunoassay used to screen for IgG autoantibodies, serving as a vital aid in diagnosing Connective Tissue Diseases (CTDs).
Specimen Requirements
Collection Container/Tube:
Preferred: Serum (Gold top)
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 2mL preferred, 1.5mL minimum
Collection Instructions: Centrifuge within 2 hours and aliquot serum into a plastic vial.
Specimen Stability
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Refrigerated (preferred) |
14 days |
| Frozen | for longer storage |
Panel Components and Reflexes
| ANAPL | Antinuclear Antibodies (ANA), Panel, Serum |
| ANASCR | Antinuclear Antibodies (ANA), Screen, Serum |
| DNASCR | Double Stranded DNA Screen, Serum |
Reference Values
ANA:
<0.7 ratio=Negative
0.7-1.0 ratio=Equivical
>1.0 ratio= Positive
DNA:
<10 IU/mL=Negaitve
10-15 IU/mL=Equivical
>15 IU/mL=Positive
Method
ImmunoCAP® Fluorescence Enzyme Immunoassay (FEIA)
CPT
86038
86225
Performing Laboratory
MaineGeneral Medical Center
Day(s) Performed
Monday - Friday