Test Code DDI D-Dimer, DIC and PE/DVT, Plasma
Performing Laboratory
MaineGeneral Medical Center
Useful For
Evaluating for PE/DVT and DIC
Reference Values
0.00-0.46 µg/mL
Day(s) Test Performed
Monday through Sunday
Specimen Requirements
Draw blood in a full, blue-top (3.2% sodium citrate) tube. The tube must be filled to a 9:1 blood to anticoagulant ratio. Invert 6 times to mix blood, and place tube in crushed ice. Spin down, remove plasma, and place 1 mL of citrate platelet-poor plasma in plastic vial. (Glass vial is not acceptable.) Label specimen with patient’s name (first and last), date of birth, date and time of draw, and phlebotomist’s initials.
Specimen rejection criteria:
Clotted or hemolyzed specimen
Hematocrit >55%
Incorrect anticoagulant
Overfilled or underfilled tubes
Specimen stability: 8 hours at toom temperature
1 month frozen at ≥-20°C
Minimum volume: 0.5 mL of citrated plasma
Test Classification and CPT Coding
85379