Sign in →

Test Code MAP Mold Allergen Panel

Useful For

Uncover environmental fungi sensitizations and/or cross-reactivity. Identify risk for development or increased severity, or respiratory disease. Determine personalized exposure reduction and appropriate referrals.

Specimen Requirements

Collection Container/Tube:

Preferred: Serum

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 2mL preferred, 1.5mL minimum 

Collection Instructions: Centrifuge within 2 hours and aliquot serum into a plastic vial.

Specimen Stability

Specimen Type Temperature Time
Serum Refrigerated (preferred)

7 days

  Frozen  90 days

Avoid multple freeze/thaw cycles.

Panel Components and Reflexes

ALTALT A. Alternata, IgE Alternaria Alternata, IgE
ASP A. fumigatis, IgE Aspergillus fumigatis, IgE
CANIGE C. albicans, IgE  Candida Albicans, IgE (Yeast)
CHERB C. Herbarum, IgE Cladosporium Herbarum, IgE
MUCOR M. racemosus, IgE Mucor racemosus, IgE

Reference Values

< 0.10 kUa/l = Negative

Please see Interpretation Guide for additional information.

Method

ImmunoCAP® Fluorescence Enzyme Immunoassay (FEIA)

CPT

86003x5

Performing Laboratory

MaineGeneral Medical Center