The determination of an individuals immune status for Measles, Mumps and Rubella.

Specimen Requirements

Serum

 

Draw blood in a gold-top (serum separater) gel tube or a red-top (no additive) tube. Label the specimen with the patient's name (first and last), date of birth, date and time of draw, the phlebotomist's initials and as serum. Spin down and send 2 mL of serum refrigerated. 

 

Specimen stability:

2 days refrigerated at 2-8°C

Freeze at ≤ -20°C for longer storage

 

Minimum volume:

2 mL

 

Reference Ranges

Measles and Mumps IgG

reported as positive, negative and equivocal

 

Rubella IgG

reported as reactive, non-reactive and equivocal

 

A positive or reactive result indicates immunity to the virus

An equivocal result should be retested to confirm

Day(s) Test Performed

Tuesday and Friday

Test Classification and CPT Coding

86735, 86765, 86762