Test Code VCBGAS Cord Blood Gas Panel, Venous
Specimen
Arterial cord blood in a heparinized syringe, without the needle, that is free from bubbles or excess air. Syringe must be labeled as a "venous" specimen. Syringes may be sent to the lab on ice but it is not necessary if delivered in a timely fashion. Clotted specimens or specimens with excess air will be rejected.
NOTE: Syringes may be labeled with Mom's name if the newborn is not registered yet. In the case of twins, Baby A and Baby B must be differentiated.
Minimum volume: 1mL
Specimen stability: 30 minutes at room temperature
Reference Values
ARTERIAL
CORD BLOOD GAS: Preterm(<37 wks) Term(>37 wks)
pH: 7.25 - 7.29 7.27 - 7.28
pCO2: 49.2 - 51.6 mmHg 49.2-50.3 mmHg
HCO3: 22.4 - 23.9 mmol/L 22.0 - 23.1 mmol/L
BE: (-)2.5 - (-)3.2 mmol/L (-)2.7 - (-)3.6 mmol/L
VENOUS CORD BLOOD GAS:
pH: 7.25-7.34
pCO2: 27-49 mmHg
pO2: 17-41 mmHg
HCO3: 15-25 mmol/L
BE: -8 to 0 mmol/L
Study performed June 2011
Day(s) Test Set Up
Monday through Sunday
Performing Laboratory
MaineGeneral Medical Center
CPT Code
82803